Univers Revers Surgical Technique

The Arthrex reverse shoulder platform is a modern inlay system that incorporates key design elements to facilitate improved stability and impingement-free range of motion while reducing intraoperative and postoperative complications.1

A wide array of humeral stems is offered, including bone-sparing short stems for simplified implant insertion and removal. Paired with the SutureCup, the humeral construct features a 135° or 155° humeral inclination angle for optimal biomechanics. In a fracture setting, the 135° humeral cup orientation promotes anatomic tuberosity restoration while numerous suture eyelets allow for reproducible and reliable osteosynthesis, all resulting in improved range of motion.2

Two unique glenoid systems provide surgeons with unrivaled flexibility and adaptability. Incremental lateralization options up to 8 mm, vault fixation via central ingrowth screw or post, and an industry-leading scope of half- and full-wedge augments lead the way to effectively treating various types of glenoid pathology.

References

1. Gobezie R, Shishani Y, Lederman E, Denard PJ. Can a functional difference be detected in reverse shoulder arthroplasty with 135° versus 155° prosthesis for the treatment of rotator cuff arthropathy: a prospective randomized study. J Shoulder Elbow Surg. 2019;28(5):813-818. doi:10.1016/j.jse.2018.11.064

2. Schmalzl J, Jessen M, Holschen M, et al. Tuberosity healing improves functional outcome following primary reverse shoulder arthroplasty for proximal humeral fractures with a 135° prosthesis. Eur J Orthop Surg Traumatol. 2020;30(5):909-916. doi:10.1007/s00590-020-02649-8

View More

The Arthrex reverse shoulder platform is a modern inlay system that incorporates key design elements to facilitate improved stability and impingement-free range of motion while reducing intraoperative and postoperative complications.1

A wide array of humeral stems is offered, including bone-sparing short stems for simplified implant insertion and removal. Paired with the SutureCup, the humeral construct features a 135° or 155° humeral inclination angle for optimal biomechanics. In a fracture setting, the 135° humeral cup orientation promotes anatomic tuberosity restoration while numerous suture eyelets allow for reproducible and reliable osteosynthesis, all resulting in improved range of motion.2

Two unique glenoid systems provide surgeons with unrivaled flexibility and adaptability. Incremental lateralization options up to 8 mm, vault fixation via central ingrowth screw or post, and an industry-leading scope of half- and full-wedge augments lead the way to effectively treating various types of glenoid pathology.

References

1. Gobezie R, Shishani Y, Lederman E, Denard PJ. Can a functional difference be detected in reverse shoulder arthroplasty with 135° versus 155° prosthesis for the treatment of rotator cuff arthropathy: a prospective randomized study. J Shoulder Elbow Surg. 2019;28(5):813-818. doi:10.1016/j.jse.2018.11.064

2. Schmalzl J, Jessen M, Holschen M, et al. Tuberosity healing improves functional outcome following primary reverse shoulder arthroplasty for proximal humeral fractures with a 135° prosthesis. Eur J Orthop Surg Traumatol. 2020;30(5):909-916. doi:10.1007/s00590-020-02649-8

View More

Educational Resources and Products

Videos
(26)
arrow_drop_down
Videos
Documents
(22)
arrow_drop_down
Documents
English
(47)
arrow_drop_down
Languages

Surgical Technique Videos (4)

Univers Revers™ Augmented Modular Glenoid System: Half-Wedge Baseplate
Patrick J. Denard, MD
05:00 | English | 05/10/2022 | VID1-003191-en-US A
Modular Glenoid System (MGS) Bone Graft Instrumentation
Justin W. Griffin, MD
11:17 | English | 02/18/2021 | VID1-001874-en-US B
Baseplate Preparation with the Univers Revers™ Universal Baseplate Impactor
Patrick J. Denard, MD
06:18 | English | 02/23/2017 | VID1-00942-EN B
Proximal Humerus Malunion Management with the Univers Revers Total Shoulder System
Anthony A. Romeo, MD
31:29 | English | 10/11/2016 | VID1-00293-EN A

Surgical Technique Animations (5)

Bone Graft Preparation for Univers Revers™ Modular Glenoid System
05:53 | English | 12/29/2022 | AN1-000277-en-US A
FxBridge™ Tuberosity Repair System: Reverse Total Shoulder Arthroplasty
03:22 | English | 01/28/2022 | AN1-000295-en-US A
Univers Revers™ Universal Glenoid™ Convertible Baseplate
02:11 | English | 12/30/2021 | AN1-00305-EN C
Univers Revers™ Total Shoulder Arthroplasty
09:03 | English | 10/29/2015 | AN1-00112-EN A

Surgical Technique Guides (7)

Univers Revers™ Modular Glenoid System
English | 01/06/2023 | LT1-00112-EN G
Univers Revers™ Fracture Adapter
English | 12/12/2022 | LT1-000178-en-US D
Univers Revers™ Augmented Modular Glenoid System
English | 12/09/2022 | LT1-000169-en-US F
Universal Glenoid™ Convertible Baseplate Surgical Technique
English | 11/19/2020 | LT1-000000-en-US C

510Ks (3)

Case Presentation Videos (1)

Managing Anterior Glenoid Bone Loss With the Univers Revers™ Augmented Modular Glenoid System (MGS)
Daniel H. Doty, MD
06:53 | English | 06/30/2022 | VID1-003258-en-US B

Coding Guides (1)

Miscellaneous (1)

Arthroplasty Patient Outreach and Education
03:53 | English | 06/21/2022 | VID1-002818-en-US B

Outcomes Reports (2)

Univers Revers™ Total Shoulder System
English | 09/04/2020 | CC1-00012-EN F
Univers Revers™ Humeral Inclination Comparison
English | 09/01/2020 | CC1-00008-EN I

Patient Education Animations (2)

Arthroplasty Patient Outreach and Education
03:53 | English | 06/21/2022 | VID1-002818-en-US B
Reverse Total Shoulder Replacement with Univers Revers™ System
03:45 | English | 03/03/2017 | PAN1-00112-EN B

Patient Education Literature (1)

A Patient’s Guide to Shoulder Replacement Surgery
English | 01/13/2023 | pLB1-000402-en-US A

Presentation Videos (8)

Glenoid Treatment Options: Managing Complex Morphology With Augmented Implants
Patrick J. Denard, MD
11:09 | English | 10/25/2021 | VID1-002712-en-US A
Reverse Total Shoulder Arthroplasty After Multiple Failed RCRs
Anthony A. Romeo, MD
03:35 | English | 05/02/2018 | VPT1-00637-EN A
Revision of Infected TSA using the Univers Revers™ Total Shoulder System
Evan S. Lederman, MD
03:15 | English | 06/23/2017 | VPT1-00866-EN A
Malunion of 3-Part Proximal Humerus Fracture
Anthony A. Romeo, MD
03:54 | English | 02/24/2017 | VPT1-00640-EN C
rTSA: Not Just for Rotator Cuff Tear Arthropathy
Sam Dubrow, MD
11:41 | English | 06/30/2016 | VPT1-00658-EN A
Proximal Humeral Fracture Treatment - Clinical Outcomes with 135 vs. 155 Degree Reverse TSA Options
Laurence D. Higgins, MD, MBA
08:21 | English | 03/01/2016 | VPT1-00610-EN A
Subscapularis Management in Reverse TSA
John Costouros, MD
09:51 | English | 09/25/2015 | VID1-00532-EN A
Arthrex Univers Revers™ Shoulder Arthroplasty
Anthony A. Romeo, MD
06:51 | English | 09/23/2014 | VPT1-00351-EN A

Product Demonstrations (5)

Univers Revers Augmented Modular Glenoid System
02:42 | English | 01/24/2023 | AN1-000088-en-US B
Arthroplasty Product Highlight Reel
00:45 | English | 03/29/2022 | VID1-003363-en-US A
Univers Revers™ Augmented Modular Glenoid System
02:35 | English | 10/29/2020 | AN1-000249-en-US A
Univers Revers™ Modular Glenoid System
02:05 | English | 06/24/2019 | AN1-000035-en-US B

Scientific Updates (2)

Surgeon Newsletters (1)

Scope This Out, Volume 23, Number 1
English | 03/14/2022 | LN1-000401-en-US A

Tray Lists (6)

Univers Revers™ Apex Humeral System Tray (AR-9501-RAB)
English | 08/26/2020 | DOC1-000400-en-US A
Modular Glenoid System (AR-9615S)
English | 12/17/2019 | DOC1-000107-en-US A
Univers Revers™ Humeral Set (AR-9501HC-1)
English | 12/05/2019 | DOC1-000109-en-US A
Univers™ CA Humeral Head Instrument Set (AR-9200CAS)
English | 11/07/2019 | DOC1-000146-en-US A
Univers Revers™ Glenoid (AR-9501GS)
English | 10/24/2019 | DOC1-000110-en-US A
Univers Revers™ CA Head Case (AR-9501HC-RCAS)
English | 09/19/2019 | DOC1-000115-en-US A






Customer ServiceLatex Information