SutureLoc™ Implant

A knotless all-suture anchor, the SutureLoc implant is specifically designed for joint-line fixation of the meniscal root. This revolutionary anchor eliminates the need for a posterior medial portal, which is commonly used in direct tibial fixation techniques, making the repair more reproducible. The 2.4 mm cannulated drill pin leaves more bone intact while delivering the SutureLasso™ wire directly to the footprint of the meniscal root. Once the anchor has been passed, the 2 repair sutures can be passed through the tissue in a variety of stitch patterns. The knotless implant is retensionable, allowing surgeons to dial in their repair.

Features and Benefits

  • Double-loaded knotless mechanism allows for 2 repair stitches with only 1 anchor pass, reducing steps from previous techniques
  • Soft, all-suture implant
  • Minimal bone removal with a smaller, 2.4 mm drill pin and no need to decorticate
  • Simple, reproducible suture passing
  • Suture tension can be controlled and adjusted under direct visualization
  • Repair sutures are converted in line, eliminating the potential for the suture to cut into bone
  • 236.8 N of pull-out strength and 0.34 mm of cyclic displacement1

Reference:

1. Arthrex, Inc. Data on file (APT-05761A). Naples, FL; 2022.

Veja Mais

A knotless all-suture anchor, the SutureLoc implant is specifically designed for joint-line fixation of the meniscal root. This revolutionary anchor eliminates the need for a posterior medial portal, which is commonly used in direct tibial fixation techniques, making the repair more reproducible. The 2.4 mm cannulated drill pin leaves more bone intact while delivering the SutureLasso™ wire directly to the footprint of the meniscal root. Once the anchor has been passed, the 2 repair sutures can be passed through the tissue in a variety of stitch patterns. The knotless implant is retensionable, allowing surgeons to dial in their repair.

Features and Benefits

  • Double-loaded knotless mechanism allows for 2 repair stitches with only 1 anchor pass, reducing steps from previous techniques
  • Soft, all-suture implant
  • Minimal bone removal with a smaller, 2.4 mm drill pin and no need to decorticate
  • Simple, reproducible suture passing
  • Suture tension can be controlled and adjusted under direct visualization
  • Repair sutures are converted in line, eliminating the potential for the suture to cut into bone
  • 236.8 N of pull-out strength and 0.34 mm of cyclic displacement1

Reference:

1. Arthrex, Inc. Data on file (APT-05761A). Naples, FL; 2022.

Veja Mais

SutureLoc™ Implant

Product Demonstrations | 00:57 | English | 08/22/2023 | VID1-004046-en-US A

SutureLoc™ Implant for Meniscal Root Repair

Product Demonstrations | 02:03 | English | 03/28/2024 | AN1-000301-en-US B
Meniscal Root Repair Using the SutureLoc™ Implant
Meniscal Root Repair Using the SutureLoc™ Implant
Matthew T. Provencher, MD
Vídeos — Técnicas cirúrgicas | 13:32 | English | 02/07/2023 | VID1-003669-en-US A
Meniscal Root Repair Using the SutureLoc™  Implant
Meniscal Root Repair Using the SutureLoc™ Implant
Guias de técnicas cirúrgicas | English | 05/03/2024 | LT1-000236-en-US D
Videos
(7)
arrow_drop_down
Videos
Documentos
(3)
arrow_drop_down
Documentos
English
(10)
arrow_drop_down
Línguas

Vídeos — Técnicas cirúrgicas (1)

Meniscal Root Repair Using the SutureLoc™ Implant
Meniscal Root Repair Using the SutureLoc™ Implant
Matthew T. Provencher, MD
13:32 | English | 02/07/2023 | VID1-003669-en-US A

Guias de técnicas cirúrgicas (1)

Meniscal Root Repair Using the SutureLoc™  Implant
Meniscal Root Repair Using the SutureLoc™ Implant
English | 05/03/2024 | LT1-000236-en-US D

510Ks (1)

SutureLoc™ Implant
SutureLoc™ Implant
English | 02/07/2023 | K223284 A

Boletins para cirurgiões (1)

Scope This Out - Volume 24, Number 2
Scope This Out - Volume 24, Number 2
English | 09/15/2023 | LN1-000522-en-US A

Product Demonstrations (3)

SutureLoc™ Implant for Meniscal Root Repair
SutureLoc™ Implant for Meniscal Root Repair
02:03 | English | 03/28/2024 | AN1-000301-en-US B
SutureLoc™ Implant
SutureLoc™ Implant
00:57 | English | 08/22/2023 | VID1-004046-en-US A
ZebraProbe and ZebraProbe Plus Demonstration
ZebraProbe and ZebraProbe Plus Demonstration
Patrick A. Smith, MD
03:17 | English | 06/07/2023 | VID1-001490-en-US A

Vídeos apresentações de casos (3)

The Evolution of All-Soft-Tissue Meniscal Allograft Transplantation
The Evolution of All-Soft-Tissue Meniscal Allograft Transplantation
J. Lee Pace, MD
07:26 | English | 05/08/2024 | VID1-003665-en-US A
Meniscal Root Repair Using the SutureLoc™ Implant
Meniscal Root Repair Using the SutureLoc™ Implant
Gautam P. Yagnik, MD
07:47 | English | 02/26/2024 | VID1-004097-en-US A
Medial Meniscus Root Repair Using the SutureLoc™ Implant: Early Outcomes and Clinical Rationale
Medial Meniscus Root Repair Using the SutureLoc™ Implant: Early Outcomes and Clinical Rationale
Justin J. Mitchell, MD
10:49 | English | 12/28/2023 | VID1-004167-en-US A

Atendimento ao clienteInformações sobre látex