Arthrex, Inc.
  • Events Calendar
  • 0 0

hammer toe


  • Procedure/Product Pages (7)
    • Trim it spin pin 0 small
      • The Trim-It Spin Pin™ offers the surgeon the advantage of exact sizing of PIPJ implants every time, without leaving pin material across the DIPJ eliminating the need to countersink. The Trim-It Spin Pin’s laser marked metal trocar tip acts as a drill and measuring device, providing for an exact fit of the bioabsorbable implant.  PLLA …
    • Foot and ankle bio screws and pins 0 small
      • Arthrex offers a variety PLLA fixation options with the Trim-It Screw and Trim-It Pin families.  The Trim-It Instrumentation Set includes the necessary instruments needed to drill, measure depth, tap and properly “cut-to-size” and retaper the tip of the 2.7 mm, 3.5 mm, 4.0 mm and 4.5 mm bio-absorbable Trim-It Screws.   Arthrex …
    • Pip joint resection 0 small
      • PIP Dart fixation offers surgeons the advantage of exact sizing of proximal interphalangeal (PIP) joint implants every time, without violating or leaving material across the distal interphalangeal joint (DIPJ). The PIP DART is made out of PEEK material and takes the guesswork out of pin placement for PIP joint fusions. The PIP Dart fixation's …
    • Interphalangeal joint fusion 0 small
      • Correction of claw or hammer toe deformity can be achieved using various techniques, including proximal interphalangeal joint arthrodesis (PIPJ).  Interphalangeal Joint Fusion can be accomplished using the Arthrex Trim-It Pins and Trim-It Spin Pins.
    • Metatarsal shortening osteotomy 0 small
      • A long lesser metatarsal can lead to common toe problems.  A shortening metatarsal is done to help to prevent future complications.  These complications include plantar plate tear, hammer toe, claw toe, and crossover toe deformity.  Once these complications have occurred, the surgeon may choose a metatarsal shorting osteotomy to …
    • Plantar plate repair 0 small
      • Using the CPR™ system, surgeons now have the option to repair the plantar plate from a dorsal approach. Following a Weil osteotomy to recess the capital fragment up to 1 cm under the metatarsal, the plantar plate is accessed using a small joint distractor clamp over K-wires. The surgeon can then use the novel Mini Scorpion™ DX suture …
    • Plantar plate tears 0 small
      • The plantar plate is made of a 2 - 5 mm thick layer of connective tissue originating on the plantar aspect of the distal metatarsals and inserting on the plantar base of the proximal phalanx.  This stout structure serves as the main stabilizer supporting the MTP joints.  Through chronic microtrauma or dynamic imbalance, this tissue can …