Translate? This website is also available in your language! Do you want to switch? Yes Not now Don't ask me again
  • Procedure/Product Pages (22)
    • Image?api id=hand and wrist 9700 series radiofrequency ablation&width=120&file type=jpg
      • Arthrex’s 9700 Series radiofrequency wands have been updated with new handles and coating along the shaft to replicate with the look of the CoolCut™ wands while preserving the features of these popular probes. The AR-9705A-90 and AR-9705-90 offer a “toothbrush” type of electrode and are the largest wands Arthrex offers. …
    • Image?api id=radio frequency wands&width=120&file type=jpg
      • Arthrex’s 9700 Series Radio Frequency wands have been updated with new handles and coating along the shaft to keep up with the look of the CoolCut wands while preserving some of the most popular probes Arthrex offers.  The AR-9705A-90 and AR-9705-90 offer a “Toothbrush” type of electrode and the largest Arthrex offers.  This probe is …
    • Image?api id=open tfcc repair&width=120&file type=jpg
      • Arthrex introduces an all-arthroscopic, knotless technique to repair peripheral ulnar tears of the articular disk. The advantage of this technique is that it repairs both superficial and deep layers (ligamentum subcrunetum) of the articular disk back-to-bone at their anatomic insertion. In addition, using a knotless technique decreases potential …
    • Image?api id=arthroscopic repair with the micro suturelasso&width=120&file type=jpg
      • Using standard wrist arthroscopy portals and setup, type 1B tears of the TFCC are repaired back to their anatomic insertion on the bone. Using a specialized Micro SutureLasso™ suture passer, a 2-0 FiberWire® suture is passed through the TFCC and a mattress stitch is created. The TFCC kit is then used to place a knotless 2.5 mm PushLock …
    • Image?api id=arthroscopic tfcc repair&width=120&file type=jpg
      • The Arthrex Micro SutureLassos were designed to facilitate repair of the TFCC, whether the dorsal or palmar capsular ligament portion is torn. Each Micro SutureLasso has a 20-gauge tip designed to be less traumatic to the TFCC and surrounding ligament during passing. Both inside/out and outside/in techniques can be used, as well as a double …
    • Image?api id=knotless repair to bone&width=120&file type=jpg
      • Using standard arthroscopic portals, the Micro SutureLasso™ are directed through the TFCC tissue adjacent to the tear. The Micro SutureLasso can be inserted using either the outside-in or inside-out techniques. A specialized 2-0 FiberStick allows direct passage of 2-0 FiberWire suture through the Micro SutureLasso and TFCC tissue. Using …
    • Image?api id=coolcut radio frequency ablation&width=120&file type=jpg
      • The OPES CoolCut™ Radio Frequency Ablation device features an innovative ergonomic handle with finger touch controls. The 90° versions have a unique shape that allows for maximum extension from the tip of the electrode to the shaft of the device, while still fitting through a 5 mm cannula. The new CoolCut shaft coating facilitates easy …
    • Image?api id=coolcut specialty length small joint&width=120&file type=jpg
      • CoolCut specialty-length shaver blades feature a wide range of high-quality, single-use shaver blades for arthroscopic surgical procedures of the ankle, wrist, and elbow. The disposable, sterile shaver blades can be used in all Arthrex shaver handpieces and inserted with the cutting window in the up or down position. Threads molded into the …
    • Image?api id=fiberlink and tigerlink&width=120&file type=jpg
      • FiberLink and TigerLink sutures are 1.3 mm SutureTape or #2 FiberWire® suture with a closed loop on one end. These sutures were designed to create cinch stitches by simply passing the suture through tissue and feeding the free end through the loop for tensioning. Lock the cinch stitch into position using the Knotless PushLock® or …
    • Image?api id=hand and wrist fiberloop&width=120&file type=jpg
      • Part of the FiberWire® suture family, FiberLoop® is FiberWire suture where both ends of the suture are attached to a single needle, creating a suture loop. FiberLoop is the perfect suture option for multi-strand tendon repairs. These small diameter looped FiberWire products allow for strong multi-strand flexor and extensor tendon repairs while …
    • Image?api id=fibersnare&width=120&file type=jpg
      • FiberSnare® is a #2 FiberWire® with a small loop on one end while the opposite end is stiffened 12 inches. This provides an easy one step approach to creating a FiberWire loop on the tip of the Bio-Tenodesis Driver. Instead of using a nitinol wire, insert the stiff non-looped end retrograde through the tip of the Bio-Tenodesis …
    • Image?api id=hand and wrist fiberstick&width=120&file type=jpg
      • FiberStick™ and TigerStick® are part of the FiberWire® family. The stiff “waxed” end of the FiberStick and TigerStick allows convenient and easy advancement through most cannulated instruments or spinal needles. By allowing simple push-through passing of FiberWire suture, it alleviates the need for a monofilament suture or wire suture …
    • Image?api id=fiberwire&width=120&file type=jpg
      • FiberWire® suture is constructed of a multi-strand, long chain ultra-high molecular weight polyethylene (UHMWPE) core with a braided jacket of polyester and UHMWPE that gives FiberWire® superior strength, soft feel and abrasion resistance that is unequaled in orthopaedic surgery. FiberWire® is the first suture on the market to offer a …
    • Image?api id=hand and wrist fiberwire tigerwire&width=120&file type=jpg
      • Trusted by leading surgeons worldwide, FiberWire suture has been used in over one million orthopedic surgical procedures. Available in 2-0, 3-0, and 4-0 and with multiple needle and length configurations, FiberWire suture is ideally suited for hand and wrist procedures.
    • Image?api id=fingershield&width=120&file type=jpg
      • The FingerShield is a woven polyester sleeve with an embedded radiopaque blue marker designed to reduce pressure induced lacerations to the digits of the hand caused by repetitive knot tying during surgery. They slip right over sterile gloves when needed. The tips are left open to allow pinch grasp of suture strands, while still protecting …
    • Image?api id=open bromstrom&width=120&file type=jpg
      • Arthrex has developed a simple, safe, and reproducible technique using the BioComposite SwiveLock® and FiberTape®. InternalBrace™ ligament augmentation repair can be used to augment to a Broström procedure. InternalBrace ligament augmentation repair allows the surgeon to correct lateral or medial ankle instability. …
    • Image?api id=hand and wrist radio frequency ablation&width=120&file type=jpg
      • The Arthrex CoolCut line of imaging and resection products includes the product families of CoolCut Radio Frequency Ablation and the 9700s Series Radio Frequency Ablation products.
    • Image?api id=hand and wrist sutures&width=120&file type=jpg
      • A major advancement in orthopedic surgery providing the ultimate in reliability and strength, FiberWire® sutures are constructed of a multi-stranded, long chain, ultra-high molecular weight polyethylene (UHMWPE) core with a braided jacket of polyester and UHMWPE. This combination provides superior strength, soft feel, and abrasion resistance …
    • Image?api id=tfcc repair kit&width=120&file type=jpg
      • The Triangular Fibrocartilage (TFCC) Ulnar Tunnel Repair technique provides a reliable and reproducible option to treat peripheral ulnar tears. By repairing both the superficial and deep layers (ligamentum subcruentum) of the TFCC down to bone, this technique recreates an anatomic TFCC insertion. FiberStick™ or FiberWire® sutures …
    • Image?api id=tfcc tears&width=120&file type=jpg
      • Triangular Fibrocartilage Complex (TFCC) injury is an increasingly recognized problem that can significantly affect wrist function, even for activities of daily living. Diagnosis and treatment of ulnar-sided wrist pain has improved with advances in technology in imaging and arthroscopy. Several techniques have been described for arthroscopic …
    • Image?api id=foot and ankle tissue resection&width=120&file type=jpg
      • Arthrex has a long history of providing innovative solutions in orthopaedic medical devices, offering advanced technology in tissue resection, maximizing patient safety, performance and efficiency, as well as providing options to assist healthcare facilities as they strive to increase OR efficiency and reduce per-procedure costs. An …
    • Image?api id=wafer excision&width=120&file type=jpg
      • The Ulnar Head Wafer procedure is used to eliminate further impingement of the distal ulna against the lunate. This impingement is commonly associated with central TFCC tears. Arthrex has developed extremely efficient, small size burrs (round and oval) to resect the few millimeters needed from the ulnar head.